Hospital Infrared Optical Spectrometer With LED display and touch panel

 

 

C13 urea breath Test, rapid test, C13 analyzer, H.pylori detector/analyzer, gastrointestinal analyzer, stomach diagnosis, clinical diagnosis, laboratory diagnosis, laboratory diagnosis instrument/device, clinic diagnosis instrument/device, medical diagnosis device. C13 Isotope tracing analyzer/device 

 

 

 Product Description:

H. Pylori Rapid Test kit:  13C Urea Breath Test for the clinical diagnosis of Helicobacter pylori (H. Pylori) infection. As 13C is a kind of stable isotope, 13C Breath Test is applicable for all ages and types of subjects, including pregnant women and young children.

 

 

 

 


The 13C-Urea Breath Test offers advantages as below:

Accurate: Sensitivity 95%, specificity 95%-100%.

Comfortable : Non-invasive, no endoscopic tube insertion, well tolerated by patients.

Convenient : Near-patient testing, analysis made on site, minimal inconvenience for patients.

Simple : Easy operation, no special handling required.

Swift : The entire test is finished in 45 minutes, test result available on site.


Operation procedure:
1. Blow up the first breath bag as baseline breath
2. Take one 13C Urea capsule and wait for 30 minutes
3. Blow up the second breath bag
4. Test two bags of breath samples with Breath Test Analyzer HCBT-01

Specification:
1. Dimension:

  1.  Weight:

3.Power supply: AC230V  50Hz/60Hz,  power consumption<250W

4,13C-Urea capsule: 75mg/grain/package
5,Breath bag: 2 pcs/package

  • 4. Range of CO2 Concentration: 1.0~6.0%
  • 5. Sample volumn: ≥120ml/bag
  • 6. Measurement time: ≤3minutes/test
  • 7. Accuracy: standard error ≤0.3‰


The 13C-Urea Breath Test offers advantages as below:
Accurate: Sensitivity 95%, specificity 95%-100%.
Comfortable: Non-invasive, no endoscopic tube insertion, well tolerated by patients.
Convenient: Near-patient testing, analysis made on site, minimal inconvenience for patients.
Simple: Easy operation, no special handling required.
Swift: The entire test is finished in 30 minutes, test result available on site.
  

 